Technical Specifications for Aerocon Panels


  • AVAILABLE SIZES

  • Available width = 600mm
  • Available thicknesses = 50mm and 75mm
  • Available lengths = 2.4 m, 2.7m and 3.0m
  

PROPERTIES OF AEROCON PANELS


PROPERTIES 50mm PANEL 75mm PANEL REMARKS
Dry weight (kg / sq.m) 39 54
Axial Load / metre width (KN/m 53 83 Factor of safety = 2.5
(samples size: 1500 x 300mm
Bending Test (4 point UDL)
Uniform Distributed Load (Kg/m sq.)
             – 2.9m Span
             – 1.9m Span
 
 
73
198
 
 
100
265
Factor of safety = 2.5
Flexural Strength /
Modulus of Rupture (Kg/sq. cm)
67 58 Typical Test Results
Compressive Strength (Kg/sq. cm) 30 40 Typical Test Results
Thermal Conductivity (W/m deg. K) 0.22 0.21 BS 4370 – Part 2
Sound Transmission Coefficient (db) 33 36 IS: 9901 (Part III) – 1981
IS: 11050 (Part I) – 1981
Fire Rating (mins)
as per tests results of CBRI
60 120 BS 476 Part 20-22
Surface speed of flame Class I Class I BS 476 Part 7 – 1971
Fire Propagation Index (I) 3.7 3.7 BS 476 Part 6 – 1981
Ignitability Class P (Not easily Ignitable) Class P (Not easily Ignitable) BS 476 Part 5 – 1968